We are Manufacturer, Supplier, Exporter of Cooling Tower With Instrumentation / Forced Drought Cooling Tower & our setup is situated in Sangli, Maharashtra, India.
Datacone Engineers & Agro Processors offers a high quality Cooling Tower With Instrumentation designed for practical training, experimentation, research and educational applications in thermal and chemical engineering. Our Cooling Tower Test Rig enables students, researchers and professionals to study cooling tower performance, heat transfer, mass transfer, temperature variation, water circulation and cooling efficiency through practical laboratory experiments. The system is suitable for engineering colleges, universities, technical institutes, research laboratories and industrial training centers. Our Instrumented Cooling Tower is designed to provide accurate measurement and practical understanding of cooling tower operations and thermal performance. The equipment helps users conduct experiments related to inlet and outlet water temperatures, air flow, water flow, cooling range, approach, evaporation losses and overall cooling tower efficiency. As reliable Cooling Tower Laboratory Equipment, it is manufactured with a focus on accuracy, durability, ease of operation and dependable performance for engineering education, research and technical training applications. Datacone Engineers & Agro Processors also provides reliable Heat Transfer Laboratory Equipment and specialized Cooling Tower Laboratory Equipment for academic practicals, student projects, technical training, research activities and thermal engineering studies. Our Cooling Tower With Instrumentation supports engineering institutions in developing practical knowledge of heat and mass transfer processes involved in industrial cooling systems. With a focus on quality manufacturing, precision, durability and reliable laboratory solutions, we serve customers across India looking for Cooling Tower Test Rig, Instrumented Cooling Tower, Heat Transfer Laboratory Equipment and Cooling Tower Laboratory Equipment.
- To determine Volumetric mass transfer coefficient (hD.a) for air-water system in a cooling tower.
- To study the temperature distribution along the height of the tower.
- The experiments can be conducted at various flow rates of Air & Water & calculation can be made accordingly.
- Experiment can be conducted on both Induced & Forced Draught condition.
- To determine & compare the efficiency of the tower from Induced & Forced Draught condition.
- Heater Assembly
- Cooling Tower size : 300 mm x 300 mm x 1200 mm.
- Packing : Expanded wire mesh (Two sets).
- Rotameter : 1.1 - 11 LPM to measure inlet water flow.
- Induced draught axial flow fan.
- Blower : Centrifugal type 3 HP.
- Orificemeter: To measure air flow.
- Water circulating pump.
- Set of thermocouples.
- 12 Channel Digital Temperature Indicator
- Switches for Pump, axial fan, heater etc.
- Main's On/Off Switch for blower.
- 2 m (L) x 1.0 m (L) table top
- 440 V AC, 3 Phase Supply, 50 Hz
- WEIGHT : @ 125 Kg